Knowing how your batteries operate in cold weather conditions can greatly help you keep track of your battery packs' health, and more importantly allow you to maintain your power needs when you need it most.

Maintaining Optimum Battery Power Levels During the Winter Months

Fred Wehmeyer | U.S. Battery Manufacturing

Partial or off-grid applications utilizing flooded lead-acid batteries perform differently during cold winter months. The reason is that FLA batteries have charge and discharge rates that depend highly upon temperature. While warmer climates tend to speed-up charging and discharging rates, cold winter months can slow down the rate of charge/discharge.  Because most flooded lead-acid batteries used in renewable energy applications are stored indoors, they're not always subjected to freezing temperatures. Nevertheless, the cold can still increase the resistance in the battery's chemistry and cause a reduction in capacity and charge acceptance. Therefore, it's important that your bank of batteries remain in a location where the temperatures can remain preferably between 50-85°F degrees (10-29°C).

A general rule of thumb a battery loses 10 percent of its capacity for every 15-20 degrees below 80 °F (27 °C).  With this in mind, you can calculate your power needs and add more battery banks to compensate. Much of this greatly depends on the conditions in which your batteries are stored.  While it may sound better to keep your battery packs closer to boilers and other sources of radiant heat, problems can arise when some batteries are warmer than others; particularly if the battery charger is connected to the batteries and to AC power for maintenance charging. Battery manufacturers recommend keeping your batteries in a room that has a consistent temperature. They also recommend that your storage area should have plenty of space between the batteries and between the walls of the enclosure so that air can circulate and help provide some insulation. Also ensure that there's ventilation in the room and that your batteries are away from any other electrical components that can cause a spark.

With the proper conditions, you can also determine the state of charge of your batteries by simply checking each one with a hydrometer. The ability to check specific gravity readings in flooded lead-acid batteries is an advantage in cold weather operation. It allows the operator to fully understand the effects of cold temperature on the batteries, and allows them to be properly maintained.  As a rule of thumb, subtract four points (.004) from your hydrometer reading for every 10 degrees below 80 °F (5.6degrees below 27 °C). For example; if the temperature of the electrolyte is 50 °F and your battery specific gravity reading is 1.200, you must subtract .012 from your reading. In this case .004 for every 10 degrees equals .012. Subtract this from 1.200 and your corrected specific gravity reading is 1.188. In this example, the battery cell is less than 50 percent charged.

Knowing how your batteries operate in cold weather conditions can greatly help you keep track of your battery packs' health, and more importantly allow you to maintain your power needs when you need it most.  For additional resources on battery maintenance and ways to increase battery efficiency and service life, visit U.S. Battery's website at www.usbattery.com

The content & opinions in this article are the author’s and do not necessarily represent the views of AltEnergyMag
US Battery

US Battery

U.S. Battery Manufacturing Company

Other Articles

Lithium Batteries for Renewable Energy Applications
Considering A Lithium Battery For Your Electrical Back-up Station? Here's Some Facts You Need To Know
The Truth About Reviving Dead Batteries
The truth is, there are many factors that contribute to poor battery performance and failure, and it is important to diagnose the symptoms of poor battery performance before determining a cure.
Battery Recycling Can Lead to a Better Future for Energy Resources
Various business sectors and local and federal government agencies are increasingly looking to lead batteries as a vital energy resource. Lead-acid batteries are nearly 100-percent recycled in a closed-loop system and represent a sustainable resource.
More about US Battery

Comments (0)

This post does not have any comments. Be the first to leave a comment below.


Post A Comment

You must be logged in before you can post a comment. Login now.

Featured Product

U.S. BATTERY RENEWABLE ENERGY SERIES DEEP CYCLE BATTERIES

U.S. BATTERY RENEWABLE ENERGY SERIES DEEP CYCLE BATTERIES

Our RE Series batteries are designed to provide the highest peak capacity, longest cycle life, and greatest reliability for use in industrial or residential renewable energy applications. Renewable Energy Series batteries utilize the company's exclusive XC2™ formulation and Diamond Plate Technology® to create the industry's most efficient battery plates, delivering greater watt-hours per liter and watt-hours per kilogram than any other flooded lead-acid battery in the market. Our Deep Cycle batteries are engineered to work with solar panels as well as other renewable energy applications.